Smartwatch irregular rhythm notifications in adults aged 75 years or older: accuracy against a 14-day patch electrocardiogram
Smartwatch notifications of irregular rhythm are increasingly received by older adults, the group at highest risk of atrial fibrillation (AF) but least represented in validation studies. We studied 398 adults aged 75 years or older without known AF who wore a 14-day patch electrocardiogram while using their own smartwatch with notifications enabled. AF lasting 30 seconds or more was found in 41 participants (10.3%). Of 37 participants notified, 31 had AF (positive predictive value 83.8%, 95% CI 68.9 to 92.3). Notifications identified 31 of 41 participants with AF (sensitivity 75.6%); 8 of the 10 who were missed had less than 1 hour of AF in total. In this age group, a notification usually indicated AF, but the absence of one did not exclude short episodes of uncertain clinical significance.
Abstract: Smartwatch irregular rhythm notifications in adults aged 75 years or older: accuracy against a 14-day patch electrocardiogramPDF: Smartwatch irregular rhythm notifications in adults aged 75 years or older: accuracy against a 14-day patch electrocardiogramReferences: Smartwatch irregular rhythm notifications in adults aged 75 years or older: accuracy against a 14-day patch electrocardiogram
External validation of a deep learning pneumothorax detector on chest radiographs: accuracy with and without chest drains at four hospitals
Background. Deep learning models for pneumothorax on chest radiographs report high accuracy, but some may detect the chest drains used to treat pneumothorax rather than the pneumothorax itself. We externally validated a pneumothorax detector and examined its accuracy in radiographs with and without a chest drain. Methods. In this retrospective diagnostic accuracy study, we assembled 5,412 adult frontal chest radiographs from 4,630 patients at four hospitals with four scanner vendors (January to June 2025), enriched for pneumothorax. The reference standard was the consensus of two thoracic radiologists, with computed tomography where available. We applied PTX-Net (version 2.0), a convolutional neural network trained on public datasets, at its prespecified threshold, and analyzed prespecified subgroups by chest drain, pneumothorax size, projection, sex, age and hospital. Results. Pneumothorax was present on 438 radiographs (8.1%). The area under the receiver operating characteristic curve was 0.927 (95% CI 0.913 to 0.940), sensitivity 84.2% (80.5 to 87.4) and specificity 93.1% (92.4 to 93.8). Sensitivity was 94.7% (90.3 to 97.2) with a chest drain and 77.5% (72.2 to 82.1) without one, and 63.6% (54.1 to 72.1) for small pneumothoraces without a drain. Specificity was 81.4% in radiographs with a drain and 94.8% without. Accuracy was similar across sex, age groups and hospitals. Conclusions. Overall accuracy overstated the model's ability to find untreated pneumothorax, the cases in which detection matters most. Pneumothorax detectors should be evaluated and reported separately for radiographs without chest drains.
Abstract: External validation of a deep learning pneumothorax detector on chest radiographs: accuracy with and without chest drains at four hospitalsPDF: External validation of a deep learning pneumothorax detector on chest radiographs: accuracy with and without chest drains at four hospitalsReferences: External validation of a deep learning pneumothorax detector on chest radiographs: accuracy with and without chest drains at four hospitals