Demo

This is a design sample, not real research. The authors, institutions, data and results are fictional. Demo articles are excluded from search engines, feeds and indexing services, and will be removed when the first articles of Volume 1 are published.

Augmented Medicine Research article Clinical Decision Support Open access Special issue: Prospective evaluation of clinical AI systems Demo

Prospective silent evaluation of a machine learning early warning score for deterioration on general wards at three hospitals

Helena M. Castellanos1, Tobias Wierzbicki2, Adaeze Nwosu-Hart3, Kenji Morimoto2, Rachel L. Abernathy4, Samir El-Khoury5 and Lindiwe Dube3

Abstract

Background. Machine learning early warning scores for ward patients are often reported from retrospective data at a single hospital, and few have been tested prospectively against the score already in use. We evaluated a gradient-boosted model (WARD-ML) in real time, without showing its output to clinicians, at three hospitals of different size.

Methods. WARD-ML was developed on 96,840 admissions to Hospital A (2021 to 2023) and validated temporally on 33,018 admissions (2024). It then ran silently in the production electronic health record at Hospitals A, B and C from February 3, 2025, to February 1, 2026. The primary outcome was unplanned intensive care unit transfer, cardiac arrest or death on the ward within 24 hours of each scored observation set. The comparator was the National Early Warning Score 2 (NEWS2). We assessed discrimination, calibration, alert performance at a prespecified threshold and net benefit.

Results. The prospective cohort comprised 41,775 admissions, of which 1,214 (2.9%) had the primary outcome. The area under the receiver operating characteristic curve was 0.842 (95% CI 0.834 to 0.850) for WARD-ML and 0.781 (0.771 to 0.791) for NEWS2, a difference of 0.061 (0.052 to 0.070). WARD-ML overestimated risk slightly (expected-to-observed ratio 1.10, 1.04 to 1.16; calibration slope 0.91, 0.88 to 0.94), most at the smallest hospital. At matched alert volumes, WARD-ML detected 781 of 1,214 events (64.3%) and NEWS2 detected 669 (55.1%), with a median lead time of 14.6 and 9.1 hours. Discrimination was lower in patients aged 80 years or older (0.812) and similar across sex and racial and ethnic groups.

Conclusions. In silent prospective use at three hospitals, WARD-ML identified more deteriorating patients than NEWS2, earlier and with fewer alerts per event detected. Whether acting on its alerts improves outcomes needs a controlled evaluation.

Keywordsclinical deterioration; early warning score; gradient boosting; prospective validation; calibration; decision curve analysis; hospital rapid response team

  1. 1Division of Hospital Medicine, Department of Medicine, Demo University School of Medicine, Columbus, OH, USA
  2. 2Center for Clinical Data Science, Demo University, Columbus, OH, USA
  3. 3Department of Biostatistics, Demo University College of Public Health, Columbus, OH, USA
  4. 4Department of Nursing Research, Demo Lakeside Community Hospital, Dublin, OH, USA
  5. 5Department of Critical Care Medicine, Demo Valley Regional Hospital, Zanesville, OH, USA

Corresponding author: Helena M. Castellanos, Division of Hospital Medicine, Department of Medicine, Demo University School of Medicine, Columbus, OH, USA. Email withheld for this demo.

Received
Revised
Accepted
Published
Volume
1 (2026), article 3
DOI
Not yet assigned
License
CC BY 4.0, copyright the authors
Peer review
Not peer reviewed (demo article)

Demo datesThe journals opened on November 2, 2026. These dates only show the layout of an article's history.

1. Introduction

Most patients who deteriorate on general wards show abnormal vital signs or laboratory results hours before an unplanned transfer to intensive care, a cardiac arrest or death. Delays in recognizing these patients are common, and each hour of delay in transfer to intensive care is associated with higher mortality [1]. Hospitals have responded with aggregate early warning scores such as the National Early Warning Score (NEWS), which assigns points to seven physiological measurements and discriminates well between patients at low and high risk of these events within 24 hours [2]. Its update, NEWS2, changed the oxygen saturation scale for patients with hypercapnic respiratory failure and added new confusion, but its ability to identify patients at risk of in-hospital death was not better than that of the original score in multicenter data [3].

Aggregate scores are simple and transparent, but they treat each measurement in isolation, ignore laboratory results and trends, and use thresholds that were set by consensus. A systematic review of early warning scores found that most development and validation studies had methodological weaknesses, including poor handling of missing data, inappropriate analysis of repeated measures and little assessment of calibration [4]. Statistical and machine learning models built from the electronic health record (EHR) address some of these limits. In multicenter retrospective data, gradient-boosted trees and random forests discriminated better than logistic regression and than aggregate scores [5], and an EHR-based score developed at Kaiser Permanente Northern California [6] was associated with lower mortality after it was deployed with a structured nursing and physician response at 19 hospitals [7].

Retrospective accuracy does not guarantee accuracy in use. When published early warning scores were compared in the same patients, their accuracy varied widely, and several widely available tools performed worse than simpler alternatives [8]. An external validation of a proprietary sepsis model in use at many hospitals found much lower discrimination than its developer had reported, with many alerts and few events detected early [9]. Performance can change between hospitals, between periods and between the retrospective data on which a model was built and the real-time data it receives in production, where values arrive late, are corrected or are missing [10,11]. These problems are a large part of the gap between promising models and clinical benefit [12,13].

We therefore evaluated a gradient-boosted early warning model, WARD-ML, in three stages: development and temporal validation in retrospective data from an academic hospital, and a one-year prospective silent evaluation at that hospital and two smaller hospitals, during which the model scored patients in real time but its output was not shown to clinicians. We compared it with NEWS2, the score that clinicians at all three hospitals used throughout the study. The aim was to decide whether the model was accurate enough, at each hospital and in each patient group, to justify a controlled evaluation of model-triggered clinical response.

2. Methods

2.1 Study design and reporting

This was a prognostic study with retrospective development, retrospective temporal validation and prospective external and temporal validation in silent mode. It is reported according to TRIPOD+AI [14]. Because the model's output did not reach clinicians, the study was not an evaluation of a clinical intervention; the design of the next stage follows DECIDE-AI [15]. The protocol and statistical analysis plan, including the primary outcome, the comparator, the alert threshold and the subgroups, were finalized on January 20, 2025, before the prospective period began.

2.2 Setting and participants

The study took place at three hospitals of Demo Health System, which share one EHR. Hospital A is an 860-bed academic medical center, Hospital B a 340-bed community hospital and Hospital C a 150-bed regional hospital that transfers critically ill patients to Hospital A when its six-bed intensive care unit (ICU) is full. We included adults aged 18 years or older admitted to a medical or surgical ward. We excluded admissions with a comfort-care-only order at admission, ward stays shorter than 4 hours and, in the prospective period, admissions during which the scoring interface failed for more than 12 consecutive hours. Obstetric, psychiatric and pediatric wards were not included. The development cohort comprised admissions to Hospital A from January 1, 2021, to December 31, 2023, the temporal validation cohort admissions to Hospital A in 2024, and the prospective cohort admissions to all three hospitals from February 3, 2025, to February 1, 2026.

2.3 Outcome

The primary outcome was a composite of unplanned transfer from a ward to an ICU (including transfer from Hospital C to the ICU of another hospital), cardiac arrest with an attempt at resuscitation on the ward, or death on the ward without a comfort-care order, within 24 hours of a scored observation set. Transfers planned in advance, such as those after elective surgery, were not counted. Outcomes were identified from EHR transfer records, the resuscitation registry and discharge records, and a random sample of 300 outcome events and 300 non-events was reviewed by two clinicians who did not see model scores; they agreed with the automated classification in 588 of 600 cases (98.0%). For each admission, only the first event was analyzed, and observation sets after it were excluded.

2.4 Intended use and model development

WARD-ML is intended to help ward nurses and rapid response teams decide which adult patients on general medical and surgical wards need an urgent bedside review, at the point in the care pathway where NEWS2 now prompts that review. It is not intended for patients in intensive care, emergency departments, obstetric or pediatric units, or for patients receiving comfort care, and it does not recommend a treatment. Its output is a predicted probability of the primary outcome within the next 24 hours.

WARD-ML uses 31 inputs: seven vital signs (respiratory rate, oxygen saturation, use of supplemental oxygen, temperature, systolic blood pressure, heart rate and level of consciousness), each with its change over the previous 6 and 24 hours; seven laboratory tests (lactate, creatinine, urea nitrogen, bicarbonate, white cell count, platelet count and total bilirubin); age; hours since arrival on the ward; and ward type. Sex, race, ethnicity and insurance were not inputs. The model is a gradient-boosted tree ensemble (XGBoost, version 1.7.6) [16]. Hyperparameters were chosen by fivefold cross-validation in the development cohort, with folds split by patient so that no patient contributed data to more than one fold. The final model has 600 trees with a maximum depth of 5, a learning rate of 0.05 and a minimum child weight of 10. The development cohort contained 3,052 outcome events, more than the minimum needed to estimate a model of this size with little overfitting [17].

A score is computed whenever a new vital sign or laboratory result is filed. Vital signs are carried forward for up to 24 hours and laboratory results for up to 72 hours; after that, or if a test was never ordered, the value is set to the median of normal values in the development cohort and a missingness indicator is set. Multiple imputation, the usual approach for missing data in retrospective analyses [18], cannot be repeated in real time with the information available at the bedside, so the same rule was used in development, validation and deployment. Predicted probabilities were calibrated by logistic recalibration in the last 12 months of the development period and were not changed afterward.

2.5 Comparator

NEWS2 was calculated from the same observation sets using the published scoring rules, with oxygen saturation scale 2 applied when it had been selected in the EHR. During the whole study, NEWS2 was displayed to nurses at all three hospitals, and a score of 5 or more prompted an urgent review by the rapid response nurse or, at Hospital C overnight, when it has no dedicated rapid response team, by the nursing supervisor and the on-call physician. NEWS2 was therefore both the comparator and the standard of care.

2.6 Silent deployment

For the prospective period, WARD-ML ran on the health system's production integration server. It received data through the same real-time interface as the EHR, scored each new observation set and wrote the score to a research database that clinicians could not access. The data science team monitored completeness of scoring daily but did not view patient-level scores or outcomes until the period ended. Scoring was interrupted for more than 12 hours on three occasions, affecting 929 admissions, which were excluded as prespecified. The model, its inputs and its threshold were not changed during the period.

2.7 Alert threshold

To compare the two scores at the same workload, the WARD-ML alert threshold was set in the temporal validation cohort as the predicted 24-hour risk at which the proportion of admissions with at least one alert matched that of NEWS2 at a score of 5 or more. This threshold was 4.0%. In alert analyses, an event counted as detected when an alert fired between 30 minutes and 48 hours before it, and repeated alerts within 12 hours were counted as one alert episode.

2.8 Statistical analysis

The unit of analysis for discrimination and calibration was the scored observation set, with the outcome defined within the following 24 hours. Discrimination was measured by the area under the receiver operating characteristic curve (AUROC) and the area under the precision-recall curve. Confidence intervals and differences between scores were estimated from 1,000 bootstrap samples drawn by patient, which accounts for the correlation between observation sets from the same patient. Calibration was assessed with calibration plots across 20 groups of predicted risk, the calibration slope, the calibration intercept (calibration-in-the-large), the ratio of expected to observed events and the integrated calibration index [19,20]. Alert performance was assessed by admission, with sensitivity, specificity and positive predictive value at the prespecified thresholds; the encounter-level AUROC of the maximum score before the event or discharge was compared with the method of DeLong and colleagues [21] as a sensitivity analysis.

Clinical utility was assessed with decision curve analysis [22,23]. For a threshold probability pt, net benefit is

NB(pt)=TPn−FPn×pt1−pt

Scroll sideways for the whole equation

(1)

where TP and FP are the numbers of true-positive and false-positive alerts and n is the number of observation sets. The threshold probability expresses how many false alerts a clinician would accept to find one true event: at 4%, a clinician would accept up to 24 false alerts to find one true event. For this analysis, NEWS2 was converted to a probability by logistic recalibration in the temporal validation cohort.

Prespecified subgroups were age group, sex, race and ethnicity, primary insurance, ward type and hospital. Race and ethnicity were self-reported at registration and recorded in the EHR in the categories shown in Table 1. Subgroup estimates are descriptive and were not adjusted for multiple comparisons. To describe failure, two clinicians reviewed the records of all prospective events that WARD-ML did not detect, and we summarized the contribution of each input to the scores of detected and undetected events with SHAP values [24]. Monthly AUROC was plotted to look for drift. Analyses used Python 3.11 (scikit-learn 1.4 and xgboost 1.7.6) and R 4.3.2.

2.9 Sample size

The prospective period was fixed at one year. Using the approach of Riley and colleagues for external validation [25], with an expected AUROC of 0.80, an outcome proportion of 3% and a target 95% confidence interval width of 0.05 for the AUROC and 0.2 for the calibration slope, we required at least 520 events in the full cohort; we expected about 1,200. Estimates for Hospital C were expected to be less precise and were reported as secondary.

2.10 Patient and public involvement

Two members of the health system's patient and family advisory council reviewed the protocol. At their request, we added ward deaths without a comfort-care order to the outcome, and we report the number of alerts per detected event, which they considered the most understandable measure of burden on nurses.

3. Results

3.1 Cohorts

Of 46,230 adult admissions with a ward stay in the prospective period, 4,455 were excluded, leaving 41,775 admissions of 33,904 patients (Figure 1). The outcome occurred in 1,214 admissions (2.9%): 1,003 unplanned ICU transfers, 74 cardiac arrests and 137 ward deaths. Patients at Hospitals B and C were older and more often insured by Medicare, and fewer were from racial and ethnic minority groups, than those at Hospital A (Table 1). The outcome was less common at the smaller hospitals: 3.2% at Hospital A, 2.8% at Hospital B and 2.3% at Hospital C. The prospective cohort contributed 2,384,915 scored observation sets, of which 23,372 (0.98%) were followed by the outcome within 24 hours.

Compared with the adult populations of the counties that the hospitals serve, the prospective cohort was older, as expected for inpatients, and its racial and ethnic composition was close to that of each hospital's catchment area. Hispanic and Asian patients made up a small share of every cohort, which limits the precision of the subgroup estimates for these groups.

Flow diagram. 46,230 adult admissions with a general ward stay at hospitals A, B and C from February 3, 2025, to February 1, 2026. 4,455 were excluded: 612 with comfort care only at admission, 2,914 with a ward stay under 4 hours and 929 during scoring interface outages. 41,775 admissions of 33,904 patients were included, 1,214 with the primary outcome (2.9%). By hospital: A, academic with 860 beds, 22,140 admissions and 701 outcomes (3.2%); B, community with 340 beds, 13,512 admissions and 372 outcomes (2.8%); C, regional with 150 beds, 6,123 admissions and 141 outcomes (2.3%). A side note gives the retrospective cohorts at hospital A: 96,840 admissions for development (2021 to 2023) and 33,018 for temporal validation (2024).

Scroll sideways for the whole figure

Figure 1. Flow of admissions through the prospective silent evaluation. The retrospective development and temporal validation cohorts, both from Hospital A, are shown for reference. The primary outcome was unplanned intensive care unit transfer, cardiac arrest or death on the ward. Demo data: fictional.
Download figure (SVG)Figure data (CSV)
Data table
StageN
Adult admissions with a general ward stay, Hospitals A, B and C (Feb 3, 2025 to Feb 1, 2026)46230
Excluded: comfort care only at admission612
Excluded: ward stay under 4 h2914
Excluded: scoring interface outage929
Excluded in total4455
Included admissions41775
Included patients33904
Included admissions with the primary outcome1214
Hospital A admissions22140
Hospital A outcomes701
Hospital B admissions13512
Hospital B outcomes372
Hospital C admissions6123
Hospital C outcomes141
Retrospective development cohort, Hospital A, 2021 to 2023 (admissions)96840
Retrospective temporal validation, Hospital A, 2024 (admissions)33018

Scroll sideways for all columns

Table 1. Characteristics of the admissions in each cohort. Percentages use the number of admissions in the column as the denominator. Outcome components are the first qualifying event in each admission. Patients admitted to more than one hospital are counted in the column of each hospital, so the prospective hospital columns sum to more than the 33,904 patients in the prospective cohort. ICU, intensive care unit; IQR, interquartile range.

CharacteristicDevelopment (A, 2021 to 2023)Temporal validation (A, 2024)Prospective, Hospital AProspective, Hospital BProspective, Hospital C
Admissions, n96,84033,01822,14013,5126,123
Patients, n68,21526,87018,10210,9564,962
Age, years, median (IQR)63 (49 to 75)64 (50 to 76)64 (50 to 76)68 (55 to 79)71 (59 to 81)
Female sex, n (%)50,329 (52.0)17,213 (52.1)11,580 (52.3)7,214 (53.4)3,226 (52.7)
Race and ethnicity, n (%)
Black19,174 (19.8)6,671 (20.2)4,560 (20.6)1,892 (14.0)241 (3.9)
Hispanic6,876 (7.1)2,510 (7.6)1,705 (7.7)1,013 (7.5)318 (5.2)
White63,627 (65.7)21,404 (64.8)14,237 (64.3)9,980 (73.9)5,393 (88.1)
Asian2,905 (3.0)1,056 (3.2)730 (3.3)270 (2.0)37 (0.6)
Other or unknown4,258 (4.4)1,377 (4.2)908 (4.1)357 (2.6)134 (2.2)
Primary insurance, n (%)
Medicare41,834 (43.2)14,528 (44.0)9,830 (44.4)7,120 (52.7)3,790 (61.9)
Medicaid17,912 (18.5)5,943 (18.0)3,920 (17.7)2,165 (16.0)905 (14.8)
Commercial31,640 (32.7)10,700 (32.4)7,155 (32.3)3,610 (26.7)1,180 (19.3)
Other or self-pay5,454 (5.6)1,847 (5.6)1,235 (5.6)617 (4.6)248 (4.1)
Surgical ward admission, n (%)32,446 (33.5)10,890 (33.0)7,380 (33.3)3,662 (27.1)1,163 (19.0)
Ward length of stay, days, median (IQR)3.9 (2.2 to 6.7)3.8 (2.1 to 6.5)3.8 (2.1 to 6.6)3.4 (1.9 to 5.8)3.1 (1.8 to 5.2)
Primary outcome, n (%)3,052 (3.2)1,036 (3.1)701 (3.2)372 (2.8)141 (2.3)
Unplanned ICU transfer2,512852583306114
Cardiac arrest on the ward19763412211
Death on the ward343121774416

Scroll sideways for all columns

Demo data: fictional.

3.2 Discrimination and calibration

In temporal validation, the AUROC was 0.857 (95% CI 0.849 to 0.865) for WARD-ML and 0.789 (0.779 to 0.799) for NEWS2. In the prospective cohort, it was 0.842 (0.834 to 0.850) for WARD-ML and 0.781 (0.771 to 0.791) for NEWS2, a difference of 0.061 (0.052 to 0.070; Table 2 and Figure 2A). WARD-ML discriminated better than NEWS2 at each hospital, although the AUROC of both scores fell with hospital size, to 0.818 and 0.764 at Hospital C. The area under the precision-recall curve was 0.071 (0.065 to 0.077) for WARD-ML and 0.043 (0.039 to 0.047) for NEWS2. In the encounter-level sensitivity analysis, the AUROC of the maximum score was 0.861 for WARD-ML and 0.803 for NEWS2 (P < 0.001).

WARD-ML was well calibrated in temporal validation (slope 0.97, intercept −0.02) but overestimated risk in the prospective cohort, with a slope of 0.91 (0.88 to 0.94), an intercept of −0.09 (−0.13 to −0.05) and an expected-to-observed ratio of 1.10 (1.04 to 1.16; Figure 2B). Overestimation was greatest at Hospital C (slope 0.84, intercept −0.18), where the outcome was least common. The integrated calibration index was 0.0021 overall.

Table 2. Discrimination and calibration for the primary outcome within 24 hours, by scored observation set. Values are estimates with 95% confidence intervals from 1,000 bootstrap samples clustered by patient. Calibration slope and intercept are for WARD-ML; an intercept below zero means that the model predicted more events than occurred. AUROC, area under the receiver operating characteristic curve; NEWS2, National Early Warning Score 2.

CohortAUROC, WARD-MLAUROC, NEWS2Difference in AUROCCalibration slopeCalibration intercept
Temporal validation, Hospital A0.857 (0.849 to 0.865)0.789 (0.779 to 0.799)0.068 (0.059 to 0.077)0.97 (0.94 to 1.00)−0.02 (−0.06 to 0.02)
Prospective, all hospitals0.842 (0.834 to 0.850)0.781 (0.771 to 0.791)0.061 (0.052 to 0.070)0.91 (0.88 to 0.94)−0.09 (−0.13 to −0.05)
Prospective, Hospital A0.851 (0.841 to 0.861)0.786 (0.773 to 0.799)0.065 (0.054 to 0.076)0.93 (0.89 to 0.97)−0.07 (−0.12 to −0.02)
Prospective, Hospital B0.834 (0.820 to 0.848)0.779 (0.762 to 0.796)0.055 (0.040 to 0.070)0.90 (0.85 to 0.95)−0.10 (−0.17 to −0.03)
Prospective, Hospital C0.818 (0.795 to 0.841)0.764 (0.737 to 0.791)0.054 (0.030 to 0.078)0.84 (0.76 to 0.92)−0.18 (−0.29 to −0.07)

Scroll sideways for all columns

Demo data: fictional.

3.3 Alerts and clinical utility

At the prespecified thresholds, the two scores alerted on a similar number of admissions: 6,512 for WARD-ML and 6,598 for NEWS2 (Table 3). WARD-ML detected 781 of the 1,214 events (64.3%, 95% CI 61.6 to 67.0) and NEWS2 detected 669 (55.1%, 52.3 to 57.9), a difference of 9.2 percentage points (6.9 to 11.5). Specificity was similar (85.9% and 85.4%), and the positive predictive value was 12.0% for WARD-ML and 10.1% for NEWS2. Nurses would have reviewed 8.3 alerted admissions for each event detected by WARD-ML and 9.9 for each event detected by NEWS2, with 4.6 and 5.2 alert episodes per 100 patient-days. Among detected events, the median time from the first alert to the event was 14.6 hours (interquartile range 5.8 to 30.2) for WARD-ML and 9.1 hours (3.2 to 21.7) for NEWS2.

Table 3. Alert performance by admission in the prospective cohort (41,775 admissions, 1,214 with the primary outcome) at the prespecified thresholds: a predicted 24-hour risk of 4.0% for WARD-ML and an aggregate score of 5 or more for NEWS2. An event counted as detected when an alert fired between 30 minutes and 48 hours before it. Alert episodes were separated by at least 12 hours. CI, confidence interval; IQR, interquartile range.

MeasureWARD-MLNEWS2
Admissions with at least one alert, n6,5126,598
Sensitivity, % (95% CI)64.3 (61.6 to 67.0), 781 of 1,21455.1 (52.3 to 57.9), 669 of 1,214
Specificity, % (95% CI)85.9 (85.5 to 86.2), 34,830 of 40,56185.4 (85.0 to 85.7), 34,632 of 40,561
Positive predictive value, % (95% CI)12.0 (11.2 to 12.8), 781 of 6,51210.1 (9.4 to 10.9), 669 of 6,598
Alerted admissions per detected event8.39.9
Alert episodes per 100 patient-days4.65.2
Lead time before the event, hours, median (IQR)14.6 (5.8 to 30.2)9.1 (3.2 to 21.7)

Scroll sideways for all columns

Demo data: fictional.

WARD-ML had higher net benefit than NEWS2 at every threshold probability from 1% to 10% (Figure 2C). At the 4% threshold, its net benefit was equivalent to 20.3 true alerts per 10,000 observation sets with no false alerts, compared with 9.8 for NEWS2. Alerting on every observation set had negative net benefit at all thresholds above 1%.

3.4 Subgroups

WARD-ML had a higher AUROC than NEWS2 in every prespecified subgroup (Figure 2D). Its discrimination decreased with age, from 0.861 (0.838 to 0.884) in patients aged 18 to 44 years to 0.812 (0.793 to 0.831) in those aged 80 years or older. Estimates were similar for women and men (0.845 and 0.839), for Black, Hispanic and White patients (0.838, 0.846 and 0.843) and for patients insured by Medicaid and Medicare (0.833 and 0.836); confidence intervals overlapped for all of these comparisons. Discrimination was higher on surgical wards (0.861) than on medical wards (0.836). Sensitivity at the alert threshold was 58.9% (182 of 309 events) in patients aged 80 years or older and 66.2% (599 of 905) in younger patients.

Four-panel figure. Panel A: receiver operating characteristic curves in the prospective cohort; the WARD-ML curve (navy, solid, AUROC 0.842) lies above the NEWS2 curve (red, dashed, AUROC 0.781) across the full range. Panel B: calibration plot for WARD-ML across 20 groups of predicted 24-hour risk from below 0.5% to about 7%; points lie slightly below the diagonal, more so at higher risk, with a calibration slope of 0.91 and an intercept of minus 0.09. Panel C: decision curves for threshold probabilities from 0.5% to 10%; WARD-ML has higher net benefit than recalibrated NEWS2 at all thresholds, about 20 versus 10 net true alerts per 10,000 observation sets at 4%, and alerting on every observation has negative net benefit above about 1%. Panel D: forest plot of AUROC for WARD-ML (navy squares with 95% confidence intervals) and NEWS2 (red open circles) in 12 subgroups by age, sex, race and ethnicity and ward type; WARD-ML is higher in every subgroup, its estimates range from 0.812 in patients aged 80 years or older to 0.861 in patients aged 18 to 44 years and on surgical wards.

Scroll sideways for the whole figure

Figure 2. Performance of WARD-ML and NEWS2 in the prospective cohort (2,384,915 observation sets from 41,775 admissions). (A) Receiver operating characteristic curves for the primary outcome within 24 hours. (B) Calibration of WARD-ML: observed against predicted risk in 20 groups of equal size, with 95% confidence intervals; the dashed line shows perfect calibration. (C) Decision curves; net benefit is expressed per 10,000 observation sets, and dots mark the 4% threshold. (D) AUROC by subgroup, with the overall WARD-ML estimate as a dotted line; NEWS2 point estimates are shown without intervals for clarity. AUROC, area under the receiver operating characteristic curve; NEWS2, National Early Warning Score 2. Demo data: fictional.
Download figure (SVG)Figure data (CSV)
Data table
PanelSeriesMeasureValue95% CI low95% CI high
A DiscriminationWARD-MLAUROC0.842
A DiscriminationNEWS2AUROC0.781
B Calibration of WARD-MLRisk group 1, predicted 24-h risk (%)Predicted risk (%)0.03
B Calibration of WARD-MLRisk group 1, observed 24-h risk (%)Observed risk (%)0.030.000.06
B Calibration of WARD-MLRisk group 2, predicted 24-h risk (%)Predicted risk (%)0.06
B Calibration of WARD-MLRisk group 2, observed 24-h risk (%)Observed risk (%)0.070.030.12
B Calibration of WARD-MLRisk group 3, predicted 24-h risk (%)Predicted risk (%)0.09
B Calibration of WARD-MLRisk group 3, observed 24-h risk (%)Observed risk (%)0.110.050.17
B Calibration of WARD-MLRisk group 4, predicted 24-h risk (%)Predicted risk (%)0.12
B Calibration of WARD-MLRisk group 4, observed 24-h risk (%)Observed risk (%)0.140.080.20
B Calibration of WARD-MLRisk group 5, predicted 24-h risk (%)Predicted risk (%)0.15
B Calibration of WARD-MLRisk group 5, observed 24-h risk (%)Observed risk (%)0.170.100.23
B Calibration of WARD-MLRisk group 6, predicted 24-h risk (%)Predicted risk (%)0.19
B Calibration of WARD-MLRisk group 6, observed 24-h risk (%)Observed risk (%)0.220.140.30
B Calibration of WARD-MLRisk group 7, predicted 24-h risk (%)Predicted risk (%)0.23
B Calibration of WARD-MLRisk group 7, observed 24-h risk (%)Observed risk (%)0.250.160.33
B Calibration of WARD-MLRisk group 8, predicted 24-h risk (%)Predicted risk (%)0.28
B Calibration of WARD-MLRisk group 8, observed 24-h risk (%)Observed risk (%)0.290.190.38
B Calibration of WARD-MLRisk group 9, predicted 24-h risk (%)Predicted risk (%)0.34
B Calibration of WARD-MLRisk group 9, observed 24-h risk (%)Observed risk (%)0.390.280.49
B Calibration of WARD-MLRisk group 10, predicted 24-h risk (%)Predicted risk (%)0.41
B Calibration of WARD-MLRisk group 10, observed 24-h risk (%)Observed risk (%)0.420.310.53
B Calibration of WARD-MLRisk group 11, predicted 24-h risk (%)Predicted risk (%)0.49
B Calibration of WARD-MLRisk group 11, observed 24-h risk (%)Observed risk (%)0.520.400.64
B Calibration of WARD-MLRisk group 12, predicted 24-h risk (%)Predicted risk (%)0.59
B Calibration of WARD-MLRisk group 12, observed 24-h risk (%)Observed risk (%)0.600.470.73
B Calibration of WARD-MLRisk group 13, predicted 24-h risk (%)Predicted risk (%)0.71
B Calibration of WARD-MLRisk group 13, observed 24-h risk (%)Observed risk (%)0.740.590.88
B Calibration of WARD-MLRisk group 14, predicted 24-h risk (%)Predicted risk (%)0.86
B Calibration of WARD-MLRisk group 14, observed 24-h risk (%)Observed risk (%)0.870.711.03
B Calibration of WARD-MLRisk group 15, predicted 24-h risk (%)Predicted risk (%)1.06
B Calibration of WARD-MLRisk group 15, observed 24-h risk (%)Observed risk (%)1.040.871.22
B Calibration of WARD-MLRisk group 16, predicted 24-h risk (%)Predicted risk (%)1.33
B Calibration of WARD-MLRisk group 16, observed 24-h risk (%)Observed risk (%)1.271.081.46
B Calibration of WARD-MLRisk group 17, predicted 24-h risk (%)Predicted risk (%)1.72
B Calibration of WARD-MLRisk group 17, observed 24-h risk (%)Observed risk (%)1.541.331.75
B Calibration of WARD-MLRisk group 18, predicted 24-h risk (%)Predicted risk (%)2.34
B Calibration of WARD-MLRisk group 18, observed 24-h risk (%)Observed risk (%)2.231.982.48
B Calibration of WARD-MLRisk group 19, predicted 24-h risk (%)Predicted risk (%)3.51
B Calibration of WARD-MLRisk group 19, observed 24-h risk (%)Observed risk (%)3.313.013.62
B Calibration of WARD-MLRisk group 20, predicted 24-h risk (%)Predicted risk (%)7.19
B Calibration of WARD-MLRisk group 20, observed 24-h risk (%)Observed risk (%)5.815.416.20
C Clinical utilityWARD-ML, threshold 1%Net benefit per 10,00051.1
C Clinical utilityNEWS2 (recalibrated), threshold 1%Net benefit per 10,00040.4
C Clinical utilityAlert on every observation, threshold 1%Net benefit per 10,000−2.0
C Clinical utilityWARD-ML, threshold 2%Net benefit per 10,00035.5
C Clinical utilityNEWS2 (recalibrated), threshold 2%Net benefit per 10,00021.7
C Clinical utilityAlert on every observation, threshold 2%Net benefit per 10,000−104.1
C Clinical utilityWARD-ML, threshold 3%Net benefit per 10,00026.0
C Clinical utilityNEWS2 (recalibrated), threshold 3%Net benefit per 10,00014.1
C Clinical utilityAlert on every observation, threshold 3%Net benefit per 10,000−208.2
C Clinical utilityWARD-ML, threshold 4%Net benefit per 10,00020.3
C Clinical utilityNEWS2 (recalibrated), threshold 4%Net benefit per 10,0009.8
C Clinical utilityAlert on every observation, threshold 4%Net benefit per 10,000−314.6
C Clinical utilityWARD-ML, threshold 5%Net benefit per 10,00016.3
C Clinical utilityNEWS2 (recalibrated), threshold 5%Net benefit per 10,0006.9
C Clinical utilityAlert on every observation, threshold 5%Net benefit per 10,000−423.2
C Clinical utilityWARD-ML, threshold 6%Net benefit per 10,00013.6
C Clinical utilityNEWS2 (recalibrated), threshold 6%Net benefit per 10,0004.8
C Clinical utilityAlert on every observation, threshold 6%Net benefit per 10,000−534.0
C Clinical utilityWARD-ML, threshold 7%Net benefit per 10,00011.2
C Clinical utilityNEWS2 (recalibrated), threshold 7%Net benefit per 10,0003.5
C Clinical utilityAlert on every observation, threshold 7%Net benefit per 10,000−647.3
C Clinical utilityWARD-ML, threshold 8%Net benefit per 10,0009.4
C Clinical utilityNEWS2 (recalibrated), threshold 8%Net benefit per 10,0002.8
C Clinical utilityAlert on every observation, threshold 8%Net benefit per 10,000−763.0
C Clinical utilityWARD-ML, threshold 9%Net benefit per 10,0007.9
C Clinical utilityNEWS2 (recalibrated), threshold 9%Net benefit per 10,0002.1
C Clinical utilityAlert on every observation, threshold 9%Net benefit per 10,000−881.3
C Clinical utilityWARD-ML, threshold 10%Net benefit per 10,0006.6
C Clinical utilityNEWS2 (recalibrated), threshold 10%Net benefit per 10,0001.4
C Clinical utilityAlert on every observation, threshold 10%Net benefit per 10,000−1002.2
D Subgroups, prospective cohortAge 18 to 44 y, WARD-MLAUROC0.8610.8380.884
D Subgroups, prospective cohortAge 18 to 44 y, NEWS2AUROC0.803
D Subgroups, prospective cohortAge 45 to 64 y, WARD-MLAUROC0.8480.8340.862
D Subgroups, prospective cohortAge 45 to 64 y, NEWS2AUROC0.788
D Subgroups, prospective cohortAge 65 to 79 y, WARD-MLAUROC0.8360.8230.849
D Subgroups, prospective cohortAge 65 to 79 y, NEWS2AUROC0.776
D Subgroups, prospective cohortAge 80 y or older, WARD-MLAUROC0.8120.7930.831
D Subgroups, prospective cohortAge 80 y or older, NEWS2AUROC0.752
D Subgroups, prospective cohortFemale, WARD-MLAUROC0.8450.8330.857
D Subgroups, prospective cohortFemale, NEWS2AUROC0.784
D Subgroups, prospective cohortMale, WARD-MLAUROC0.8390.8280.850
D Subgroups, prospective cohortMale, NEWS2AUROC0.778
D Subgroups, prospective cohortBlack, WARD-MLAUROC0.8380.8180.858
D Subgroups, prospective cohortBlack, NEWS2AUROC0.775
D Subgroups, prospective cohortHispanic, WARD-MLAUROC0.8460.8140.878
D Subgroups, prospective cohortHispanic, NEWS2AUROC0.783
D Subgroups, prospective cohortWhite, WARD-MLAUROC0.8430.8330.853
D Subgroups, prospective cohortWhite, NEWS2AUROC0.782
D Subgroups, prospective cohortAsian, other or unknown, WARD-MLAUROC0.8290.7950.863
D Subgroups, prospective cohortAsian, other or unknown, NEWS2AUROC0.770
D Subgroups, prospective cohortMedical ward, WARD-MLAUROC0.8360.8260.846
D Subgroups, prospective cohortMedical ward, NEWS2AUROC0.776
D Subgroups, prospective cohortSurgical ward, WARD-MLAUROC0.8610.8450.877
D Subgroups, prospective cohortSurgical ward, NEWS2AUROC0.797

Scroll sideways for all columns

3.5 Events that WARD-ML did not detect

Of the 433 events that WARD-ML did not detect, 148 (34.2%) occurred within 8 hours of arrival on the ward, when few observations had been recorded; 91 (21.0%) were transfers or arrests caused by a single acute event without earlier physiological change, such as gastrointestinal hemorrhage, stroke or a new arrhythmia; and 64 (14.8%) followed a 24-hour period in which vital signs had been recorded less often than every 8 hours. The remaining 130 (30.0%) showed no common pattern. NEWS2 had alerted before 52 of the 433 events, most often on the basis of a single high respiratory rate. In undetected events, SHAP values showed that low contributions from laboratory inputs, which were often missing early in the stay, explained most of the difference from detected events.

Across all scored observation sets, the inputs that contributed most to WARD-ML predictions were respiratory rate and its 24-hour change, use of supplemental oxygen, lactate, urea nitrogen, heart rate and age. Inputs absent from NEWS2, namely laboratory results and trends in vital signs, accounted for 41% of the total contribution, which is consistent with the model's advantage being largest when laboratory results were available.

3.6 Stability over time

The monthly AUROC of WARD-ML in the prospective cohort ranged from 0.826 to 0.857, with no trend. The expected-to-observed ratio was above 1 in all 12 months, which suggests a stable difference in outcome rates between the development and deployment periods rather than progressive drift.

4. Discussion

4.1 Principal findings

In a year of silent real-time operation at three hospitals, a gradient-boosted early warning model discriminated better than NEWS2 overall, at each hospital and in every prespecified subgroup. At the same alert volume, it would have identified 112 more of 1,214 deteriorating patients, with a longer median lead time (14.6 against 9.1 hours) and fewer admissions to review for each event found. Its advantage was smaller than in retrospective validation, it overestimated risk at all three hospitals, and it was least accurate in the smallest hospital and in the oldest patients.

4.2 Comparison with other studies

The size of the difference between WARD-ML and NEWS2 is similar to differences reported between machine learning models and aggregate scores in multicenter retrospective data [5], and the absolute AUROC of NEWS2 in our cohort is within the range reported for aggregate scores [2,4]. Unlike many earlier reports, the estimates here come from data as they arrived in the production system, not from a cleaned research extract. The decline from temporal to prospective validation, 0.015 in AUROC, is much smaller than the declines that have been reported for some proprietary models in external validation [9], probably because WARD-ML was developed at one of the deployment sites on the same EHR and was tested in temporal validation before deployment [26]. The fall in discrimination at the smaller hospitals, where patients were older and outcomes rarer, is a reminder that performance at a development site cannot be assumed elsewhere [10,27].

Alert burden is the main practical barrier to early warning systems [28]. Prospective studies of sepsis alerts have shown that the number of alerts can change sharply with patient mix [29], and that the benefit of an early warning system depends on how often clinicians engage with its alerts and how quickly they act [30,31]. We matched alert volume to the score already in use, so that any future trial would compare scores at a workload that nurses already accept, and we report alerts per event detected as a direct measure of that workload.

The mortality benefit reported after deployment of the Advance Alert Monitor came from the combination of a score and a structured response: alerts were reviewed remotely by trained nurses before bedside teams were contacted, and the response included goals-of-care discussions [7]. A model is one part of such a system. At Hospital C, which has no dedicated rapid response team at night, the same alert would lead to a different response than at Hospital A, so the effect of deploying WARD-ML is likely to differ between hospitals even if its accuracy were the same. This argues for evaluating the score and the response together, and for reporting results by hospital.

4.3 Strengths and limitations

The study's strengths are its prespecified protocol and threshold, a full year of real-time scoring at three hospitals of different size, the comparison with the score in clinical use, the reporting of calibration and clinical utility as well as discrimination, and an analysis of the events that the model missed.

It also has limitations. First, NEWS2 was in clinical use and triggered rapid response review. Interventions prompted by NEWS2 may have prevented some deteriorations, which would make NEWS2 appear less sensitive, while transfers that followed NEWS2-prompted reviews may have made it appear more sensitive. The net direction of this bias is unknown, and it will also affect any deployed model once its alerts change care [11]. Second, the composite outcome includes ICU transfer, which depends on bed availability and local practice; this may explain part of the lower performance at Hospital C, which transfers patients to another hospital. Third, the three hospitals share one EHR and one health system, so the results may not apply to hospitals with different documentation practices. Fourth, subgroup estimates for small groups, especially Asian patients and patients of other or unknown race and ethnicity, are imprecise, and similar AUROC does not guarantee similar benefit: a score that is equally accurate in each group can still be applied to groups that differ in access to care [32]. Fifth, a silent evaluation shows what a model would have flagged, not whether clinicians would act on its alerts or whether acting would help.

4.4 Implications

Before WARD-ML is shown to clinicians, its predicted probabilities should be recalibrated at each hospital, especially at Hospital C, using the methods recommended for updating prediction models [33]. The lower sensitivity in patients aged 80 years or older needs further work, for example on the role of frailty and of treatment limitation decisions that are not recorded as comfort care. The next stage, which the health system has planned as a stepped-wedge cluster randomized trial with registration before enrollment, should measure patient outcomes, nurse workload and the response to each alert. Health systems that deploy any early warning model should continue to monitor calibration and alert volume after deployment, because the patients, the data and the clinical response will change [11,13].

5. Conclusions

A machine learning early warning model run silently in real time for one year at three hospitals identified more deteriorating ward patients than NEWS2, earlier and with fewer alerts per event detected, but it overestimated risk and was less accurate in the smallest hospital and in the oldest patients. Recalibration by site and a randomized evaluation of model-triggered response are the necessary next steps.

Declarations

Ethics approval and consent to participate
The study was approved by the Demo University Institutional Review Board (approval DEMO-IRB-2024-0117, November 12, 2024), which waived the requirement for informed consent because the model's output was not shown to clinicians and only data recorded in routine care were used. The study followed the Declaration of Helsinki. Registration: the study did not assign patients or clinicians to an intervention and was not registered; the protocol and statistical analysis plan were finalized on January 20, 2025, before the prospective period, and are available from the corresponding author. (Demo statement: no such approval exists.)
Data availability
The data are electronic health records of Demo Health System and cannot be shared publicly under the terms of the institutional review board approval. Aggregate data underlying the figures and tables are available from the corresponding author. Researchers may apply for access to de-identified data through the Demo University Center for Clinical Data Science; requests are reviewed by its data access committee and require a data use agreement. Code and model availability: code for data processing, model training and evaluation is deposited in the Demo University research repository under the MIT License. The trained model is not publicly available because it is integrated with the health system's production systems; a full description of the model, its inputs and its hyperparameters is given in the Methods.
Use of generative AI
Not applicable to the fictional study. This demonstration article was drafted with the help of a generative AI tool so that the journal's article design could be previewed; it reports no real research.
Funding
This research received no specific funding. The authors' institution had no role in the design, analysis, interpretation or decision to submit.
Competing interests
The authors declare no competing interests.
Author contributions (CRediT)
Conceptualization
HMC, SE
Data curation
TW, KM
Formal analysis
AN, LD
Methodology
HMC, AN, LD
Software
TW, KM
Investigation
RLA, SE
Writing, original draft
HMC
Writing, review and editing
all authors
AN and LD accessed and verified the underlying data. All authors approved the final version and agree to be accountable for the work.
Acknowledgments
This is a demonstration article created to preview the journal's design. The study, its data and its authors are fictional.

References

  1. 1.Churpek MM, Wendlandt B, Zadravecz FJ, Adhikari R, Winslow C, Edelson DP. Association between intensive care unit transfer delay and hospital mortality: a multicenter investigation. J Hosp Med. 2016;11(11):757-762. doi:10.1002/jhm.2630 DOIGoogle Scholar
  2. 2.Smith GB, Prytherch DR, Meredith P, Schmidt PE, Featherstone PI. The ability of the National Early Warning Score (NEWS) to discriminate patients at risk of early cardiac arrest, unanticipated intensive care unit admission, and death. Resuscitation. 2013;84(4):465-470. doi:10.1016/j.resuscitation.2012.12.016 DOIGoogle Scholar
  3. 3.Pimentel MAF, Redfern OC, Gerry S, et al. A comparison of the ability of the National Early Warning Score and the National Early Warning Score 2 to identify patients at risk of in-hospital mortality: a multi-centre database study. Resuscitation. 2019;134:147-156. doi:10.1016/j.resuscitation.2018.09.026 DOIGoogle Scholar
  4. 4.Gerry S, Bonnici T, Birks J, et al. Early warning scores for detecting deterioration in adult hospital patients: systematic review and critical appraisal of methodology. BMJ. 2020;369:m1501. doi:10.1136/bmj.m1501 DOIGoogle Scholar
  5. 5.Churpek MM, Yuen TC, Winslow C, Meltzer DO, Kattan MW, Edelson DP. Multicenter comparison of machine learning methods and conventional regression for predicting clinical deterioration on the wards. Crit Care Med. 2016;44(2):368-374. doi:10.1097/CCM.0000000000001571 DOIGoogle Scholar
  6. 6.Kipnis P, Turk BJ, Wulf DA, et al. Development and validation of an electronic medical record-based alert score for detection of inpatient deterioration outside the ICU. J Biomed Inform. 2016;64:10-19. doi:10.1016/j.jbi.2016.09.013 DOIGoogle Scholar
  7. 7.Escobar GJ, Liu VX, Schuler A, Lawson B, Greene JD, Kipnis P. Automated identification of adults at risk for in-hospital clinical deterioration. N Engl J Med. 2020;383(20):1951-1960. doi:10.1056/NEJMsa2001090 DOIGoogle Scholar
  8. 8.Edelson DP, Churpek MM, Carey KA, et al. Early warning scores with and without artificial intelligence. JAMA Netw Open. 2024;7(10):e2438986. doi:10.1001/jamanetworkopen.2024.38986 DOIGoogle Scholar
  9. 9.Wong A, Otles E, Donnelly JP, et al. External validation of a widely implemented proprietary sepsis prediction model in hospitalized patients. JAMA Intern Med. 2021;181(8):1065-1070. doi:10.1001/jamainternmed.2021.2626 DOIGoogle Scholar
  10. 10.Futoma J, Simons M, Panch T, Doshi-Velez F, Celi LA. The myth of generalisability in clinical research and machine learning in health care. Lancet Digit Health. 2020;2(9):e489-e492. doi:10.1016/S2589-7500(20)30186-2 DOIGoogle Scholar
  11. 11.Finlayson SG, Subbaswamy A, Singh K, et al. The clinician and dataset shift in artificial intelligence. N Engl J Med. 2021;385(3):283-286. doi:10.1056/NEJMc2104626 DOIGoogle Scholar
  12. 12.Kelly CJ, Karthikesalingam A, Suleyman M, Corrado G, King D. Key challenges for delivering clinical impact with artificial intelligence. BMC Med. 2019;17(1):195. doi:10.1186/s12916-019-1426-2 DOIGoogle Scholar
  13. 13.Sendak MP, Ratliff W, Sarro D, et al. Real-world integration of a sepsis deep learning technology into routine clinical care: implementation study. JMIR Med Inform. 2020;8(7):e15182. doi:10.2196/15182 DOIGoogle Scholar
  14. 14.Collins GS, Moons KGM, Dhiman P, et al. TRIPOD+AI statement: updated guidance for reporting clinical prediction models that use regression or machine learning methods. BMJ. 2024;385:e078378. doi:10.1136/bmj-2023-078378 DOIGoogle Scholar
  15. 15.Vasey B, Nagendran M, Campbell B, et al. Reporting guideline for the early-stage clinical evaluation of decision support systems driven by artificial intelligence: DECIDE-AI. Nat Med. 2022;28(5):924-933. doi:10.1038/s41591-022-01772-9 DOIGoogle Scholar
  16. 16.Chen T, Guestrin C. XGBoost: a scalable tree boosting system. In: Proceedings of the 22nd ACM SIGKDD International Conference on Knowledge Discovery and Data Mining. Association for Computing Machinery; 2016:785-794. doi:10.1145/2939672.2939785 DOIGoogle Scholar
  17. 17.Riley RD, Ensor J, Snell KIE, et al. Calculating the sample size required for developing a clinical prediction model. BMJ. 2020;368:m441. doi:10.1136/bmj.m441 DOIGoogle Scholar
  18. 18.Sterne JAC, White IR, Carlin JB, et al. Multiple imputation for missing data in epidemiological and clinical research: potential and pitfalls. BMJ. 2009;338:b2393. doi:10.1136/bmj.b2393 DOIGoogle Scholar
  19. 19.Van Calster B, McLernon DJ, van Smeden M, Wynants L, Steyerberg EW. Calibration: the Achilles heel of predictive analytics. BMC Med. 2019;17(1):230. doi:10.1186/s12916-019-1466-7 DOIGoogle Scholar
  20. 20.Austin PC, Steyerberg EW. The Integrated Calibration Index (ICI) and related metrics for quantifying the calibration of logistic regression models. Stat Med. 2019;38(21):4051-4065. doi:10.1002/sim.8281 DOIGoogle Scholar
  21. 21.DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics. 1988;44(3):837-845. doi:10.2307/2531595 DOIGoogle Scholar
  22. 22.Vickers AJ, Elkin EB. Decision curve analysis: a novel method for evaluating prediction models. Med Decis Making. 2006;26(6):565-574. doi:10.1177/0272989X06295361 DOIGoogle Scholar
  23. 23.Vickers AJ, van Calster B, Steyerberg EW. A simple, step-by-step guide to interpreting decision curve analysis. Diagn Progn Res. 2019;3(1):18. doi:10.1186/s41512-019-0064-7 DOIGoogle Scholar
  24. 24.Lundberg SM, Erion G, Chen H, et al. From local explanations to global understanding with explainable AI for trees. Nat Mach Intell. 2020;2(1):56-67. doi:10.1038/s42256-019-0138-9 DOIGoogle Scholar
  25. 25.Riley RD, Snell KIE, Archer L, et al. Evaluation of clinical prediction models (part 3): calculating the sample size required for an external validation study. BMJ. 2024;384:e074821. doi:10.1136/bmj-2023-074821 DOIGoogle Scholar
  26. 26.Bedoya AD, Futoma J, Clement ME, et al. Machine learning for early detection of sepsis: an internal and temporal validation study. JAMIA Open. 2020;3(2):252-260. doi:10.1093/jamiaopen/ooaa006 DOIGoogle Scholar
  27. 27.Collins GS, Dhiman P, Ma J, et al. Evaluation of clinical prediction models (part 1): from development to external validation. BMJ. 2024;384:e074819. doi:10.1136/bmj-2023-074819 DOIGoogle Scholar
  28. 28.Ancker JS, Edwards A, Nosal S, Hauser D, Mauer E, Kaushal R. Effects of workload, work complexity, and repeated alerts on alert fatigue in a clinical decision support system. BMC Med Inform Decis Mak. 2017;17(1):36. doi:10.1186/s12911-017-0430-8 DOIGoogle Scholar
  29. 29.Wong A, Cao J, Lyons PG, et al. Quantification of sepsis model alerts in 24 US hospitals before and during the COVID-19 pandemic. JAMA Netw Open. 2021;4(11):e2135286. doi:10.1001/jamanetworkopen.2021.35286 DOIGoogle Scholar
  30. 30.Adams R, Henry KE, Sridharan A, et al. Prospective, multi-site study of patient outcomes after implementation of the TREWS machine learning-based early warning system for sepsis. Nat Med. 2022;28(7):1455-1460. doi:10.1038/s41591-022-01894-0 DOIGoogle Scholar
  31. 31.Henry KE, Adams R, Parent C, et al. Factors driving provider adoption of the TREWS machine learning-based early warning system and its effects on sepsis treatment timing. Nat Med. 2022;28(7):1447-1454. doi:10.1038/s41591-022-01895-z DOIGoogle Scholar
  32. 32.Obermeyer Z, Powers B, Vogeli C, Mullainathan S. Dissecting racial bias in an algorithm used to manage the health of populations. Science. 2019;366(6464):447-453. doi:10.1126/science.aax2342 DOIGoogle Scholar
  33. 33.Steyerberg EW. Clinical prediction models: a practical approach to development, validation, and updating. 2nd ed. Springer; 2019. doi:10.1007/978-3-030-16399-0 DOIGoogle Scholar

About this article

Journal
Augmented Medicine: Artificial Intelligence in Health and Medicine
Volume and article
Volume 1 (2026), article 3
Article type and section
Research article, Clinical Decision Support
DOI
Not yet assigned. Crossref membership pending.
Publisher
Eldenhall Sciences Inc., Harrisonville, Missouri, United States
History
Demo dates: received June 2, 2026; revised August 4, 2026; accepted August 27, 2026; published September 15, 2026
Peer review
Not peer reviewed: this is a demo article. A published article names its review model here (double-blind, external reviewers) and its handling editor.
License
Creative Commons Attribution 4.0 International (CC BY 4.0)
Status
Demo article for the site design. Not real research, not indexed, not citable.

Rights and citation

Copyright 2026 the authors. This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, provided the original authors and source are credited.

Castellanos HM, Wierzbicki T, Nwosu-Hart A, Morimoto K, Abernathy RL, El-Khoury S, et al. Prospective silent evaluation of a machine learning early warning score for deterioration on general wards at three hospitals. Augment. Med. 2026;1:3. Available from: https://eldenhall.org/articles/ward-deterioration-early-warning-prospective-evaluation/ [Demo article]

Eldenhall Sciences
Sign in Submit manuscript

Search

Filters for journal, article type and year are on the results page.